DPDP ActCore duties apply from 13 May 2027 — is your evidence ready?Take the free DPDP assessmentFree assessment →
Home / OT security
OT security · add-on

Your plant, seen. Never touched.

A listen-only OT Security agent learns every controller, understands 15 industrial protocols and detects attacks on the plant, feeding the same AI Brain as your IT. It never sends a packet to the plant.

The plant, layer by layer

Every layer watched. Not one packet sent.

Plants are built in layers, from the business network down to the sensors and valves on the line (the Purdue model used by IEC 62443). Phynix listens on a mirror port, learns who normally talks to whom, and raises a lead the moment traffic crosses a layer it should not.

  • L4Enterprise ITERP, e-mail, office PCs
  • DMZIndustrial DMZthe only door between IT and OT
  • L3Site operationshistorian, MES, engineering station
  • L2SupervisoryHMI and SCADA
  • L1Basic controlPLCs and RTUs
  • L0Processsensors, drives, valves: never touched
Listen only

Listens. Learns. Never transmits.

Sensor

On a mirror port, silent

A small sensor on a SPAN or TAP port listens to plant traffic and sends signed summaries to the appliance. It never transmits on the plant network.

  • No agents on controllers or HMIs
  • No change to the plant
Protocols

Speaks the plant's language

15 industrial protocols, including Modbus, Siemens S7, OPC UA, DNP3, EtherNet/IP, PROFINET, BACnet, IEC 104 and IEC 61850.

  • Vendor, model and firmware learned from traffic
Inventory

Every controller, by Purdue level

PLCs, HMIs, engineering stations and historians, placed by Purdue level, with who talks to whom.

Detect

Attacks on the plant, caught early.

Detection

Mapped to MITRE ATT&CK for ICS

Unexpected controller logins, writes, logic and firmware downloads, new talkers and remote access, grouped into campaigns.

Risk

Plant risk in one number

Each device scored on impact, threat, vulnerability and exposure; attack paths to critical controllers.

  • Purdue segmentation score
Standards

IEC 62443 and NIST SP 800-82

Plant posture against both, with CEA and NCIIPC views for review by your auditor.

Act safely

One brain for IT and the plant.

Same AI Brain

IT and OT in one picture

OT findings feed the same incidents, AI Brain and CEO board, so a plant risk is a business risk.

Runbooks

14 OT runbooks

Step-by-step plans for plant incidents, for your engineers to carry out.

  • Response actions never touch OT devices
Views

OT wall and 3D plant

A control-room wall and a 3D plant view by Purdue level, made for operations and the board room.

Deploy

Ready in an afternoon.

OT Security is an add-on for Pro or Enterprise, included in the 30-day trial. Findings are leads, not verdicts.

StepWhat happens
1. Mirror portYour network team mirrors the plant switch (SPAN) or adds a TAP
2. SensorInstall the sensor (small VM or box) on that port; it reports to the Phynix appliance
3. LearnPhynix learns normal plant communication, then flags what is new
4. ReviewInventory, risks and posture on the OT pages and the CEO board
Talk to us

See it on your own network.

A 2-day health check, then a 15-day live pilot. Write to us or book a live demo.

office@phynix.co.in
Book a live demo